Braided Cable

50Ω Low Loss Braided Foam Coaxial Cable KNC

KANTENNA Type M9000010-V00 M9000011-V00 M9000020-V00 M9000021-V00
Cable Type KNC-195 KNC-195R KNC-200 KNC-200R
Construction
Inner Conductor Copper Wire Copper Wire Copper Wire Copper Wire
Inner Conductor Size (mm) 0.94 0.94 1.12 1.12
Shielding Construction Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape
Braid Coverage (%) >90 >90 >90 >90
Outer Conductor Size (mm) 2.95 2.95 2.95 2.95
Jacket PE FRPE PE FRPE
Cable Diameter (mm) 4.95 4.95 4.95 4.95
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 12.7 / 50.8 12.7 / 50.8 12.7 / 50.8 12.7 / 50.8
Bending Moment (Nm) 0.30 0.30 0.30 0.30
Tensile Strength (N) 176 176 180 180
Flat Plate Crush Strength (N/mm) 3 3 3 3
Storage Temp. (PE Jacket) (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +85 -20 to +60 -40 to +85 -20 to +60
Operating Temp. (°C) -40 to +85 -30 to +80 -40 to +85 -30 to +80
Cable Weight (kg/km), reference only 36 42 38 45
Electrical Characteristics
Characteristic Impedance (ohm) 50 50 50 50
Capacitance (pF/m) 79.7 79.7 79.7 79.7
Velocity (%) 80 80 83 83
Insulation Resistance (MΩ/km) > 5000 > 5000 > 5000 > 5000
DC Breakdown Voltage (V) 1000 1000 1000 1000
Inner Conductor Contact DC Resistance (/km) 24.93 24.93 24.93 24.93
Outer Conductor Contact DC Resistance (/km) 16.07 16.07 16.07 16.07
Peak Power Rating (kW) 2.5 2.5 2.5 2.5
Jacket Spark Voltage (Vrms) 2500 2500 2500 2500
Shielding Attenuation (dB) > 90 > 90 > 90 > 90
Operating Frequency (MHz) 30 - 6000 30 - 6000 30 - 6000 30 - 6000
Cut-off Frequency (GHz) 41 41 41 41
VSWR 1.15
(30-3000MHz)
1.15
(30-3000MHz)
1.15
(30-3000MHz)
1.15
(30-3000MHz)
1.20
(3-6GHz)
1.20
(3-6GHz)
1.20
(3-6GHz)
1.20
(3-6GHz)
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
150 14.43 14.43 12.45 12.45
450 25.58 25.58 21.97 21.97
900 36.41 36.41 31.80 31.80
2000 55.43 55.43 50.16 50.16
2500 62.32 62.32 57.37 57.37
4000 79.87 79.87 76.07 76.07
Typical Average Power
Frequency (MHz) Average Power (kW)
150 0.39 0.39 0.45 0.45
450 0.22 0.22 0.26 0.26
900 0.16 0.16 0.18 0.18
2000 0.1 0.1 0.12 0.12
2500 0.09 0.09 0.11 0.11
4000 0.08 0.08 0.09 0.09

 

 

KANTENNA Type M9000030-V00 M9000031-V00 M9000040-V00 M9000041-V00
Cable Type KNC-240 KNC-240R KNC-300 KNC-300R
Construction
Inner Conductor Copper Wire Copper Wire Copper Wire Copper Wire
Inner Conductor Size (mm) 1.42 1.42 1.78 1.78
Shielding Construction Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape
Braid Coverage (%) >90 >90 >90 >90
Outer Conductor Size (mm) 4.52 4.52 4.98 4.98
Jacket PE FRPE PE FRPE
Cable Diameter (mm) 6.1 6.1 7.62 7.62
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 19.1 / 63.5 19.1 / 63.5 22 / 76 22 / 76
Bending Moment (Nm) 0.30 0.30 0.38 0.38
Tensile Strength (N) 360 360 540 540
Flat Plate Crush Strength (N/mm) 4 4 5 5
Storage Temp. (PE Jacket) (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +85 -20 to +60 -40 to +85 -20 to +60
Operating Temp. (°C) -40 to +85 -30 to +80 -40 to +85 -30 to +80
Cable Weight (kg/km), reference only 55 64 76 88
Electrical Characteristics
Characteristic Impedance (ohm) 50 50 50 50
Capacitance (pF/m) 79.8 79.8 79.1 79.1
Velocity (%) 83 83 85 85
Insulation Resistance (MΩ/km) > 5000 > 5000 > 5000 > 5000
DC Breakdown Voltage (V) 1500 1500 2000 2000
Inner Conductor Contact DC Resistance (/km) 11.10 11.10 6.95 6.95
Outer Conductor Contact DC Resistance (/km) 12.76 12.76 8.50 8.50
Peak Power Rating (kW) 5.6 5.6 10 10
Jacket Spark Voltage (Vrms) 2500 2500 3500 3500
Shielding Attenuation (dB) > 90 > 90 > 90 > 90
Operating Frequency (MHz) 30 - 6000 30 - 6000 30 - 6000 30 - 6000
Cut-off Frequency (GHz) 31 31 24.5 24.5
VSWR 1.15
(30-3000MHz)
1.15
(30-3000MHz)
1.15
(30-3000MHz)
1.15
(30-3000MHz)
≤ 1.25
(3-6GHz), L≤7m
≤ 1.25
(3-6GHz), L≤7m
≤ 1.25
(3-6GHz), L≤7m
≤ 1.25
(3-6GHz), L≤7m
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
150 10.20 10.20 7.90 7.90
450 17.40 17.40 13.10 13.10
900 24.90 24.90 19.40 19.40
2000 38.68 38.68 29.80 29.80
2500 42.31 42.31 33.80 33.80
4000 53.92 53.92 44.61 44.61
Typical Average Power
Frequency (MHz) Average Power (kW)
150 0.66 0.66 0.92 0.92
450 0.38 0.38 0.52 0.52
900 0.26 0.26 0.36 0.36
2000 0.17 0.17 0.24 0.24
2500 0.15 0.15 0.21 0.21
4000 0.12 0.12 0.16 0.16

 

 

KANTENNA Type M9000050-V00 M9000051-V00 M9000060-V00 M9000061-V00
Cable Type KNC-400 KNC-400R KNC-500 KNC-500R
Construction
Inner Conductor CCA Wire CCA Wire CCA Wire CCA Wire
Inner Conductor Size (mm) 2.74 2.74 3.61 3.61
Shielding Construction Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape
Braid Coverage (%) >90 >90 >90 >90
Outer Conductor Size (mm) 8.08 8.08 9.55 9.55
Jacket PE FRPE PE FRPE
Cable Diameter (mm) 10.29 10.29 12.71 12.71
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 25.4 / 101.6 25.4 / 101.6 31.8 / 127 31.8 / 127
Bending Moment (Nm) 0.70 0.70 2.37 2.37
Tensile Strength (N) 730 730 1180 1180
Flat Plate Crush Strength (N/mm) 7 7 9 9
Storage Temp. (PE Jacket) (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +85 -20 to +60 -40 to +85 -20 to +60
Operating Temp. (°C) -40 to +85 -30 to +80 -40 to +85 -30 to +80
Cable Weight (kg/km), reference only 106 126 140 160
Electrical Characteristics
Characteristic Impedance (ohm) 50 50 50 50
Capacitance (pF/m) 78.0 78.0 77.5 77.5
Velocity (%) 85 85 86 86
Insulation Resistance (MΩ/km) > 5000 > 5000 > 5000 > 5000
DC Breakdown Voltage (V) 2500 2500 3000 3000
Inner Conductor Contact DC Resistance (/km) 4.69 4.69 2.69 2.69
Outer Conductor Contact DC Resistance (/km) 5.61 5.61 4.16 4.16
Peak Power Rating (kW) 16 16 22 22
Jacket Spark Voltage (Vrms) 4000 4000 4000 4000
Shielding Attenuation (dB) > 90 > 90 > 90 > 90
Operating Frequency (MHz) 30 - 6000 30 - 6000 30 - 6000 30 - 6000
Cut-off Frequency (GHz) 16.2 16.2 10.3 10.3
VSWR 1.20
(30-2800MHz)
1.20
(30-2800MHz)
1.20
(30-3000MHz)
1.20
(30-3000MHz)
≤ 1.25
(2.8-6GHz)
≤ 1.25
(2.8-6GHz)
≤ 1.25
(3-6GHz)
≤ 1.25
(3-6GHz)
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
150 4.92 4.92 3.93 3.93
450 8.86 8.86 7.21 7.21
900 12.80 12.80 10.17 10.17
2000 19.40 19.40 15.75 15.75
2500 22.00 22.00 18.00 18.00
4000 28.87 28.87 23.31 23.31
Typical Average Power
Frequency (MHz) Average Power (kW)
150 1.47 1.47 1.93 1.93
450 0.58 0.58 1.09 1.09
900 0.44 0.44 0.75 0.75
2000 0.37 0.37 0.49 0.49
2500 0.33 0.33 0.43 0.43
4000 0.25 0.25 0.32 0.32

 

 

KANTENNA Type M9000070-V00 M9000071-V00 M9000080-V00 M9000081-V00
Cable Type KNC-600 KNC-600R KNC-900 KNC-900R
Construction
Inner Conductor CCA Wire CCA Wire CCA Wire CCA Wire
Inner Conductor Size (mm) 4.47 4.47 6.65 6.65
Shielding Construction Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape Tinned Copper Wire Aluminum Tape
Braid Coverage (%) >90 >90 >90 >90
Outer Conductor Size (mm) 12.50 12.50 17.42 17.42
Jacket PE FRPE PE FRPE
Cable Diameter (mm) 14.99 14.99 22.10 22.10
Mechanical Characteristics
Bending Radius (Single / Repeated) (mm) 38.1 / 152.4 38.1 / 152.4 76.2 / 228.6 76.2 / 228.6
Bending Moment (Nm) 3.70 3.70 12.20 12.20
Tensile Strength (N) 1590 1590 3450 3450
Flat Plate Crush Strength (N/mm) 11 11 18 18
Storage Temp. (PE Jacket) (°C) -70 to +85 -30 to +80 -70 to +85 -30 to +80
Installation Temp. (°C) -40 to +85 -20 to +60 -40 to +85 -20 to +60
Operating Temp. (°C) -40 to +85 -30 to +80 -40 to +85 -30 to +80
Cable Weight (kg/km), reference only 216 254 400 480
Electrical Characteristics
Characteristic Impedance (ohm) 50 50 50 50
Capacitance (pF/m) 76.0 76.0 76.0 76.0
Velocity (%) 87 87 87 87
Insulation Resistance (MΩ/km) > 5000 > 5000 > 5000 > 5000
DC Breakdown Voltage (V) 4000 4000 5000 5000
Inner Conductor Contact DC Resistance (/km) 1.74 1.74 1.77 1.77
Outer Conductor Contact DC Resistance (/km) 5.75 5.75 1.80 1.80
Peak Power Rating (kW) 40 40 62 62
Jacket Spark Voltage (Vrms) 8000 8000 8000 8000
Shielding Attenuation (dB) > 90 > 90 > 90 > 90
Operating Frequency (MHz) 30 - 6000 30 - 6000 30 - 5800 30 - 5800
Cut-off Frequency (GHz) 10.2 10.2 7 7
VSWR 1.20
(30-3000MHz)
1.20
(30-3000MHz)
1.25
(30-3000MHz)
1.25
(30-3000MHz)
≤ 1.25
(3-6GHz)
≤ 1.25
(3-6GHz)
≤ 1.40
(3-6GHz)
≤ 1.40
(3-6GHz)
Typical Attenuation (Max. Attenuation Value is at 105% of the Nominal Attenuation Value)
Frequency (MHz) Attenuation (dB/100m)
150 3.20 3.20 2.20 2.20
450 5.60 5.60 3.80 3.80
900 8.20 8.20 5.60 5.60
2000 12.80 12.80 8.60 8.60
2500 14.80 14.80 9.80 9.80
4000 19.36 19.36 13.00 13.00
Typical Average Power
Frequency (MHz) Average Power (kW)
150 2.4 2.41 3.89 3.89
450 1.35 1.35 2.19 2.19
900 0.93 0.93 1.51 1.51
2000 0.58 0.58 0.97 0.97
2500 0.52 0.52 0.86 0.86
4000 0.38 0.38 0.64 0.64

 

 

Remarks:    
1) All values are typical.  Please consult Kantenna Sales Reps for detail specifications and individual datasheets.
2) Customized designs are available upon discussion.
3) Data are subjected to change without prior notice.

 

 

We represent high quality and produce products in the highest calibre.